HZ-7021 Tyre Diffusion And Solubility Coefficient Test +Tire Air Tightness Tester
OVERVIEW
Applicable Industry:
Tire air tightness tester applies to the plastic film, complex film, sheet of gas at various temperatures
through the air permeability, solubility coefficient, diffusion coefficient and permeability coefficient of
determination.
Technical Characteristics:
- The principle of differential pressure method, GB, ISO, ASTM and other global standards-compliant
- Three-cavity independent testing can be issued by each chamber of the independent data, the average of the combination of cavity statistics
- The world's most high-precision, high vacuum, impartial third party data, the objective
- Peripheral temperature control device can be any temperature within the range of 5 ~ 95 °C, the penetration test
- Humidity generating device optional test is easy to realize differential pressure method under different
- Buy the world's well-known components, stable and reliable performance
- Conventional, non-standard double test mode selection
- Super software support, solubility, diffusion and permeability coefficient automatic calculation of an Excel
- The amount of ventilation, diffusion coefficient, solubility coefficient and permeability coefficient, any
- Can be easily obtained -273 °C ~ 200 C Material permeability, permeability coefficient, solubility
- Operating intelligent test, the test process automation
- Equipment performance is ultra stable, continuous operation, and more to improve test efficiency
- Data reproducibility, human operating error
- Low systematic error of the blank test, the overall performance is better than similar products at home
- Reference diaphragm calibration, easy to operate
Technical Parameters:
Model | HZ-7021 Tire air tightness tester |
Test range | 0.05~50,000cm3/m2•24h•0.1MPa(Conventional) ceiling of not less than 500,000cm3/m2•24h•0.1MPa (Expansion volume) Note:Conventional and extended volume by volume to fill the block to select |
Temperature range | 5~95°C(Aqueous media) |
Temperature accuracy | ±0.1°C |
Humidity control range | 0%RH,2%RH~98.5%,100%RH(The humidity generating device optional) |
Humidity control accuracy | ±1%RH |
Vacuum precision | 0.1Pa |
Test chamber vacuum | <20Pa |
Test gas | O2,N2,CO2 etc |
Test pressure | -0.1MPa~+0.1Mpa |
Gas supply pressure | 0.4MPa ~ 0.6MPa |
Specimen size | Φ97mm |
Number of samples | 3 |
Through the area | 38.48cm2 |
Host size | 760mm(L)×575mm(B)×450mm(H) |
Power supply | AC 220V 50Hz |
Weight | 88kg |
Implementation Of Standards:
GB1038,ASTM D1434,ISO2556,ISO 15105-1,JIS K7126-A,YBB 00082003